DI - 200
The DI-200 Dialler interface module is designed to operate with both PM1020 & PM1025 outstations, and provides a universal alarm panel dialler interface. This module can be utilised on any alarm panel that can communicate via the Contact ID (CID) reporting format.
The choice is simple. The choice is Permaconn
Key Features
- Contact ID panel dialler lead interface.
- Monitors and reports PSTN failure.
- Monitors and reports Dialler interface failure
- Complies with Class 3 AS/NZ 2201.5 (2008)
- Small size 70 x 50 x 20 mm easy to mount in alarm panel enclosure
- Automatic switching between PSTN and GPRS
- Monitors and reports status of alarm panel interface lead
- Alarm panel status monitor input
- Non-volatile memory stores all setup information in the event of a power failure
- Jumper select for PSTN primary reporting
- Various LED status indicators for easy onsite diagnostics
- Opertates on 13.8V DC power supplied by Alarm Panel
The choice is simple. The choice is Permaconn